Network Ready NEXUS Resolver
Interface For Industrial Control |
Engineered to provide absolute position and velocity
data directly to the network, the four resolver channels
can be configured three different ways: (4) single resolver
inputs, (2) dual resolver multiturn inputs, and (2)
single resolver inputs + (1) dual resolver multiturn
input.
With 13-bit resolution for single resolver applications
and 20-bit resolution for dual resolver applications,
the NX2A4_can be used in applications ranging from metal
stamping to high speed assembly and to overhead cranes.
Whether your application calls for a single-turn resolver,
multi-turn resolver, or some combination of both, the
NEXUS resolver interface is the solution.
In addition to the above functionality, the NX2A4_
also has a brake input that provides stopping time and
brake applied position to the network. This information
can be used for brake wear monitoring thereby ensuring
operator safety.
| Network
Ready NEXUS Resolver Interface For Industrial Control |
AMCI Model #
(please specify network when ordering) |
NX2A4_
Configured for Single
Resolver Transducers |
NX2A4_
Configured for Dual Resolver Multiturn Transducers |
| Network availability |
NX2A4C (ControlNet)
NX2A4D (DeviceNet)
NX2A4E (Ethernet IP)
NX2A4P (Profibus)
NX2A4T (Modbus TCP/IP) |
NX2A4C (ControlNet)
NX2A4D (DeviceNet)
NX2A4E (Ethernet IP)
NX2A4P (Profibus)
NX2A4T (Modbus TCP/IP) |
| Position sensor |
Resolver |
Resolver |
| Number of channels |
4 maximum |
2 maximum |
| Maximum full scale count |
8192 counts for single resolver transducers |
4096 counts / turn for dual resovler multiturn
transducers |
| Position update time |
200us |
200us |
| DC supply requirements |
500 mA @24Vdc |
500 mA @24Vdc |
| Transducer compatibility |
|
HTT-20
/ HTT-400
/ HTT-425 |
| Cable requirements |
CTL-X
(X = length in feet) |
CML-X
(X = length in feet) |
Resolver Input
Connectors
(2 per unit) |
AMCI Part # = MS-8
Phoenix Contact Part # = MSTB2.5/8-ST-5.08
Two connectors are included with the unit
Each connector has three possible wiring configurations;
one Single Turn Resolver, Two Single Turn Resolvers,
or One Multiturn Resolver
One Single Turn Resolver (One CTL-X cable)

Two Single Turn Resolvers (Two CTL-X
cables)
One Multiturn Resolver (One CML-X cable)
|
| Required hardware |
na |
na |
| Optional hardware |
na |
na |
| Additional network device interfaces
& controllers by AMCI:
|